Pepper-computer Modular Computers RS485 User Manual Page 203

  • Download
  • Add to my manuals
  • Print
  • Page
    / 320
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 202
SMART I/O Users Manual
©1996 PEP Modular Computers GmbHMarch 12, 1996 Page 5 - 47
5
Chapter 5 Analog Modules
5.2.8.10 SMADCGetMode
Syntax
error_code SMADCGetMode(u_int8 PortNr, u_int8 channel,
u_int8 *pBuffer);
Description
This function checks if an SM-PT100 board is fitted on the specified port and
if the channel is valid. It gets the mode setting of the channel and stores the
value in a user defined buffer. The user has to take care that the buffer is
large enough to store the data.
Input
u_int8 PortNr
Port number to fetch the mode
(0 to 10)
u_int8 channel
Number of specified channel (0 to 3)
u_int8 *pBuffer
Pointer to a user defined buffer
Output
error_code SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
E_PARAM
If wrong channel number is specified
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCGetMode(0, 1, &Buffer);
Page view 202
1 2 ... 198 199 200 201 202 203 204 205 206 207 208 ... 319 320

Comments to this Manuals

No comments