SMART I/O User’s Manual
March 12, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 72
Chapter 5 Analog Modules
5.3.8.6 SMADCGetSensorType
Syntax
error_code SMADCGetSensorType(u_int8 PortNr, u_int8
channel, u_int16 *pBuffer);
Description
This function checks if an SM-THERM board is fitted on the specified port
and if the channel is valid. It gets the code of the sensor type of the specified
channel and stores it in a user defined buffer. The user has to take care that
there is enough place to store the data. A list of PEP supported sensor types
can be found in the file linear.h.
Input
u_int8 PortNr
Port number from which to fetch sensor type
(from 0 to 10)
u_int8 channel
Number of specified channel (0 to 3)
u_int16*pBuffer
Pointer to a user defined buffer
Output
error_code SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
E_PARAM
If wrong channel number is specified
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCGetSensorType(0, 1, &Buffer);